Fitur
Informasi Dasar
Tempat asal:
CINA
Nama merek:
OEM
Sertifikasi:
CE Certification
Nomor model:
OEM
Dokumen:
Brosur Produk PDF
Syarat Pembayaran & Pengiriman
Kuantitas min Order:
Bisa dinegosiasikan
Harga:
Bisa dinegosiasikan
Kemasan rincian:
Karton, palet, kotak kayu atau sesuai dengan persyaratan paket pelanggan
Waktu pengiriman:
30 hari kerja
Syarat-syarat pembayaran:
Setoran 30% + 70% T/T Sebelum pengiriman
Menyediakan kemampuan:
20 set per bulan
Deskripsi produk
Natural Circulation Gas Fired Steam Boiler For Steam Cleaning Industry
Product introduction
- Industrial steam boiler uses the most mature three-pass all wet back structure in the world,boiler is safe and reliable.
- The use of waveform furnace can strengthen disturbance of smoke, increasing the heat transfer area of radiation, which can not only enhance the heat transfer effect, and also promote oil combustion in the furnace.
- The entire heating surface is in symmetrical arrangement with strong structure and reasonable system of water cycle.
- Horizontal structure, large combustion chamber design, large furnace, large water capacity and good steam quality.
- The special furnace setting and the flushing method of the flue gas to the hot surface effectively reduce the heat loss of the boiler to a minimum.
Parameter
Rated evaporation | t/h | 0.5 | 1 | 1.5 | 2 | 3 | 4 | 6 | 8 | |
Rated working pressure | MPa | 0.7 | 1 | 1 | 1 | 1 | 1.25 | 1.25 | 1.25 | |
Staturated steam temperature | ℃ | 170 | 184 | 184 | 184 | 184 | 193 | 193 | 193 | |
Fuel consumption | Light diesel oil | kg/h | 35 | 70 | 105 | 140 | 210 | 260 | 390 | 520 |
Natural gas | Nm³/h | 40 | 80 | 120 | 160 | 240 | 280 | 420 | 560 | |
LPG | Nm³/h | 15 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
City gas | Nm³/h | 85 | 170 | 250 | 340 | 510 | 680 | 1020 | 1360 | |
a Main steam valve diameter | DN | 40 | 65 | 65 | 80 | 80 | 100 | 125 | 150 | |
b Safety valve diameter | DN | 40 | 50 | 50 | 40×2 | 40×2 | 50×2 | 65×2 | 80×2 | |
c Inlet diamater | DN | 25 | 25 | 40 | 40 | 40 | 50 | 50 | 65 | |
d Blowoff Valve diameter | DN | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | |
e Chimney diameter | DN | 250 | 300 | 350 | 400 | 450 | 500 | 650 | 800 | |
Overall size | L | mm | 3800 | 4500 | 4700 | 4800 | 5500 | 6310 | 7200 | 7780 |
L1 | mm | 3100 | 3200 | 3600 | 3800 | 4500 | 5230 | 5960 | 6320 | |
W | mm | 1900 | 2300 | 2800 | 2900 | 2900 | 2950 | 3190 | 3440 | |
W1 | mm | 1000 | 1880 | 1900 | 2150 | 2350 | 2350 | 2650 | 2980 | |
H | mm | 2100 | 2680 | 2950 | 3250 | 3880 | 3120 | 3610 | 3700 | |
H1 | mm | 1800 | 1980 | 2070 | 2250 | 2450 | 2530 | 2850 | 2920 | |
Weight | T | 3.3 | 4.6 | 5.5 | 6.3 | 10.6 | 13.8 | 18.5 | 20 |
Advantage
1 . Wave furnace design
2 . Three-return structure
3 . Heat evenly
4 . Endothermic balance
5 . Energy saving, low consumption, safety